This specification covers cylindrical corrosion-resistant tanks made of commercial-grade glass-fiber-reinforced polyester or vinylester thermoset resin fabricated by filament winding for above-ground vertical installation, to contain aggressive chemicals at atmospheric pressure as classified herein. This specification does not address the design of vessels intended for pressure above ...
This standard is issued under the fixed designation D 3299; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscript epsilon (e) indicates an editorial change since the last revision or reapproval. This standard has been approved ...
ASTM International - ASTM D3299-18 Standard Specification for Filament-Wound Glass-Fiber-Reinforced Thermoset Resin Corrosion-Resistant Tanks
This specification covers cylindrical corrosion-resistant tanks made of commercial-grade glass-fiber-reinforced polyester or vinylester thermoset resin fabricated by filament winding for above-ground vertical installation, to contain aggressive chemicals at atmospheric pressure as classified herein. This specification does not address the design of vessels intended for pressure above ...
ASTM D3299 Standard Specification for Filament-Wound Glass-Fiber-Reinforced Thermoset Resin Corrosion-Resistant Tanks
Designation: D3299竏・/font>18 Standard Speci・…ation for Filament-Wound Glass-Fiber-Reinforced Thermoset Resin Corrosion-Resistant Tanks1 This standard is issued under the ・』ed designation D3299; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision.
This specification covers cylindrical tanks fabricated by filament winding for above-ground vertical installation, to contain aggressive chemicals at atmospheric pressure as classified herein, and made of a commercial-grade polyester or vinylester resin. Included are requirements for materials,properties, design, construction, dimensions, tolerances,workmanship, and appearance.1.2 This ...
ASTM D3299-18 - ABSTRACT This specification covers cylindrical corrosion-resistant tanks made of commercial-grade glass-fiber-reinforced polyester or vinylester thermoset resin fabricated by filament winding for above-ground vertical installation, to contain aggressive chemicals at atmospheric pressure as classified herein. This specification does not address the design of vessels intended for ...
1.1 This specification covers cylindrical tanks fabricated by filament winding for above-ground vertical installation, to contain aggressive chemicals at atmospheric pressure as classified herein, and made of a commercial-grade polyester or vinylester resin. Included are requirements for materials, properties, design, construction, dimensions, tolerances, workmanship, and appearance.
Currently we face one tough issue which is our hypochlorite storage Tank Fabrication Standard.Vendor propose ASTM D3299 as per their experience* client require RTP-1* cost difference between both is huge.We request vendor to give explanation how come the difference* vendor clarify as below: o ASME RTP-1 demands to have a laminate where the axial and radial mechanical characteristics are ...