为您找到"

inclined plane tracking 是什么测试

"相关结果约100,000,000个

ASTM D2303 - Inclined-Plane Tracking and Erosion Tester

Overview The LEC-2303 test system provides a safe, simplified test system for the performance of ASTM D2303 - Inclined-Plane Tracking and Erosion (also in compliance with the IEC 60587 test standard). This test system is capable of performing one or more tests at a time and removes the need for constant sample monitoring with automated trip detection. […]

Astm D2303绝缘材料液态污染,斜面漏电痕迹和腐蚀标准试验方法_美国_各国标准法规_防火测试中心_防火资源网

1.1 These test methods cover the evaluation of the relative tracking and erosion resistance of insulating solids using the liquid-contaminant, inclined-plane test. The following test methods also can be used to evaluate the tracking resistance of materials: D 2132 (contaminants: dust and fog) and D 3638 (contaminant: conductive liquid drops).

2652-2021 - IEEE Guide for DC Inclined Plane Tracking and ... - IEEE Xplore

Scope: This guide is based on the knowledge and experience accumulated over a decade of using the inclined plane tracking and erosion test setup with direct current (dc) voltages for the evaluation of tracking and erosion resistance of outdoor insulating materials. This guide discusses various important aspects that need to be considered for conducting a feasible test under dc voltages.

inclined plane tracking 是什么测试 - 百度知道

inclined plane tracking 是什么测试你好!inclined plane tracking 斜面跟踪

漏电起痕指数cti - 百度文库

Inclined-Plane Tracking and Erosion of Insulating Materials》 该 标准与其它类似标准方法有区别。 ASTM D3638-93 UL746A GB/T 4207-84:固体绝缘材料在潮湿条件下相比漏电起痕指数和耐 漏电起痕指数的测定方法 GB/T 4207-2003 idt IEC 60112-1979 固体绝缘材料在潮湿条件下 相比电痕化指数和 ...

(PDF) Inclined-Plane Tracking and Erosion Test According to the IEC ...

The experimental results indicated that tracking and erosion resistance of different polymeric insulating materials were successfully evaluated and ranked by inclined-plane tracking and erosion ...

IEEE Std 2652-2021 室外绝缘应用的直流斜面跟踪和侵蚀测试 IEEE 指南 标准全文

IEEE Std 2652-2021的标准全文信息,本指南旨在适当使用直流电压进行斜面漏电起痕和侵蚀试验,以评估高压户外绝缘材料的耐漏电起痕和耐侵蚀性。This guide is intended for a suitable use of dc voltages with the inclined plane tra

PDF Standard Test Methods for Liquid-Contaminant, Inclined-Plane Tracking ...

tracking and erosion resistance of insulating solids using the liquid-contaminant, inclined-plane test.2 The following test methods also can be used to evaluate the tracking resistance of materials: D2132 (contaminants: dust and fog) and D3638 (contaminant: conductive liquid drops). 1.2 Two tracking and one erosion test procedure are de-scribed:

Tracking Index Test - Hackaday

This test is often referred as the inclined plane tracking and erosion test and specifies test voltages up to 6 kV. But for now, let's just look at the low voltage test as per IEC 60112. Procedure

Ieee 2652-2021 室外绝缘应用的直流斜面跟踪和侵蚀测试 Ieee 指南 标准全文

IEEE 2652-2021的标准全文信息,室外绝缘应用的直流斜面跟踪和侵蚀测试 IEEE 指南, IEEE Guide for DC Inclined Plane Tracking and Erosion Test for Outdoor Insulation Applications, 提供IEEE 2652-20

相关搜索